CompletedPhase 4MS (type not specified)NCT024661912014-005548-17

What it found

Result in a paper, not read yet

A paper reports the results; we have not read it yet. See Papers below.

What was tested

Treatment tested

  • Memantine
  • Gabapentin

    Voltage-gated calcium channel modulator

Compared with

  • Memantine

What it measured

Main measures

  • Velocity, amplitude and frequency of nystagmus using eye movement recording

    at Day 17-21

    Nerve conduction tests
  • Velocity, amplitude and frequency of nystagmus using eye movement recording

    at Day 34-42

    Nerve conduction tests
  • Velocity, amplitude and frequency of nystagmus using eye movement recording

    at Day 64-79

    Nerve conduction tests
  • Velocity, amplitude and frequency of nystagmus using eye movement recording

    at Day 81-100

    Nerve conduction tests
  • Clinical examination :All patients undergo a thorough ophthalmic examination including fundi and best corrected visual acuity measurement

    Vision

Other measures (12)

  • Functional score on questioning as measured by the 25-Item National Eye Institute Visual Function Questionnaire

    at Day 17-21

    Vision
  • Functional score on questioning as measured by the 25-Item National Eye Institute Visual Function Questionnaire

    at Day 34-42

    Vision
  • Functional score on questioning as measured by the 25-Item National Eye Institute Visual Function Questionnaire

    at Day 64-79

    Vision
  • Functional score on questioning as measured by the 25-Item National Eye Institute Visual Function Questionnaire

    at Day 81-100

    Vision
  • subjective measure of oscillopsia

    at Day 17-21

  • subjective measure of oscillopsia

    at Day 34-42

  • subjective measure of oscillopsia

    at Day 64-79

  • subjective measure of oscillopsia

    at Day 81-100

  • far visual acuity as measured by monocularly and binocularly direction and amplitude (measures in degrees) of their oscillopsia while viewing, with best correction, a stationary target at far (5 m) and near (57 cm) location.

    at Day 17-21

    Vision
  • far visual acuity as measured by monocularly and binocularly direction and amplitude (measures in degrees) of their oscillopsia while viewing, with best correction, a stationary target at far (5 m) and near (57 cm) location.

    at Day 34-42

    Vision

Who could take part

MS (type not specified) · 18 and over

Inclusion Criteria: * Patients with a diagnosis of oculopalatal tremor (OPT), following a focal brainstem lesion. * All patients may present a chronic acquired pendular nystagmus due to OPT, observed over a period of 6 months. * All patients will be informed about the design and purpose of the study, and all will give their informed, written consent to the protocol, which may have been approved by the local ethics committee. * Age: above 18 * Able to understand the instructions * Having a health coverage * Able to sit down for 1 hour * Stable dosage of previous medications (beginning 3 weeks previously and terminating at the end of the trial duration), except gabapentin or memantine. * For women: efficient contraception during the experimental time and in the two month following treatment withdrawal. Exclusion Criteria: * Ophthalmological * Other ophthalmological disorder that could impair corrected visual acuity (Maculopathy, Retinopathy…) * Neurological * Ongoing seizure * Severe handicap that does not allow sitting down position for 1 hour * Suicidal behavior or risk * Treatment * Under memantine or gabapentin medication (these medications should have been stopped for at least 1 week for gabapentin and 3 weeks for memantine) * Under morphine, N-methyl-D-aspartate such as amantadine, ketamine or dextromethorphan * Steroid medication for a current relapse (beginning 3 weeks previously and terminating at the end of the trial duration * Known hypersensitivity to memantine or gabapentin * General * Unstable medical state * Patient with a galactose intolerance, a lapp lactase deficiency or glucose-galactose malabsorption * Moderate renal failure (creatinine clearance \< 50 mL/min on bioassay dated from less than one month) * Recent heart infarction (\<3months) * Unstable congestive heart insufficiency * Unstable arterial hypertension * Leucopenia (\<2500/mm3) * Transaminase increase (>5 time normal values) * Pregnancy (on questioning) * Tutelage or any legal protection measure

As registered. Criteria can change, so ask the trial team or your neurologist.

About this trial

In the sponsor's words

Pendular nystagmus corresponds to an enduring to and fro eye oscillation without resetting quick phases. The most common causes of acquired pendular nystagmus (APN) are multiple sclerosis (MS) and focal brainstem lesions (oculopalatal tremor, OPT). Based on pathophysiological hypothesis, pharmacological treatments of acquired nystagmus have been thoroughly proposed over different publications of cases, series, reviews or expert opinions. Acquired pendular nystagmus underwent the most rigorous treatment trials, leading to the proposal of gabapentin or memantine as valuable drugs. Whether gabapentin and memantine are effective in APN associated with OPT remains unclear, since none of the previous studies has evaluated the effect of these medications in a group of OPT patients. However, this is an important issue in prospect to a clinical use of these medications. In the current study, the investigators aim is to evaluate the effect of gabapentin and memantine on the mean velocity, amplitude and frequency of pendular nystagmus, as well as on visual acuity and vision-specific health-related quality of life score, in a group of OPT patients

Papers

Loading reviews and guidelines…

Related trials

History

    1. Started

      Jun 2015

    2. Main results due

      Jan 2016

    3. Finished

      Jan 2016

    Assembled by software from public sources and not checked by people. Each record links to its source. Report an error