Effect of Hybrid Assistive Limb (HAL) Application on Locomotor Function and Balance Parameters in Multiple Sclerosis Patients

CompletedNot a drug-phase studyMS (type not specified)NCT07326852

What it found

No results found

We found no results in the registry or in papers.

What was tested

Treatment tested

  • Hybrid Assistive Limb (HAL)

What it measured

Main measures

  • 10-Meter Walk Test (10mWT)

    Baseline (study start) and at 2 months.

    Walking and mobility
  • Timed Up and Go Test (TUG)

    Baseline (study start) and at 2 months.

    Walking and mobility
  • 6-Minute Walk Test (6MWT)

    Baseline (study start) and at 2 months.

    Walking and mobility
  • Balance performance assessed using the TecnoBody D-Wall system

    Baseline (study start) and at 2 months.

    Walking and mobility
  • Stride Length Assessed by TecnoBody Walker View

    Baseline and at 2 months

    Walking and mobility
  • Walking Speed Assessed by TecnoBody Walker View

    Baseline and at 2 months

    Walking and mobility
  • Double Support Time Assessed by TecnoBody Walker View

    Baseline and at 2 months

    Walking and mobility
  • Gait Symmetry Index Assessed by TecnoBody Walker View

    Baseline and at 2 months

    Walking and mobility

Other measures (1)

  • Disease severity assessed by the Expanded Disability Status Scale (EDSS)

    Baseline (study start) and at 2 months.

    Disability progression

Who could take part

MS (type not specified) · 18 to 50

Show the full criteria

Inclusion criteria

* No previous robotic rehabilitation. * Completion of the 10-meter walk test. * Mini mental status score ≥24. * MASS score \<2. * EDSS \<6.

Exclusion criteria

* History of serious degenerative disease. * Presence of open wounds. * History of thoracic surgery. * Chronic respiratory diseases. * Presence of unstable cardiovascular disease. * Medical conditions that prevent mobilization.

As registered. Criteria can change, so ask the trial team or your neurologist.

About this trial

In the sponsor's words

The Hybrid Assistive Limb (HAL) exoskeleton detects bioelectrical signals from the muscles, responds to the intention of voluntary movement, and provides biological feedback. In this study, the effects of HAL application on walking performance and balance in patients with multiple sclerosis will be examined in a single-center, controlled design. Participants will undergo walking rehabilitation with HAL for 1 hour per day, 5 days a week, for a total of 2 months. Walking and balance performance will be assessed before and after the intervention using the 10-Minute Walk Test (10MWT) to measure maximum walking speed, the 6-Minute Walk Test (6MWT) to evaluate walking endurance and cardiorespiratory performance, and the Timed Up and Go Test (TUG) to assess functional mobility and dynamic balance. Additionally, walking parameters and static balance will be measured using Tecnobody systems. Appropriate statistical tests will be applied, and a significance level of p\<0.05 will be considered.